June 17, 2009 by admin

Future TCI Issues and Industry

The following perspective was presented as an abstract by Fresenius-Kabi at the Second World Congress of TIVA-TCI held in Berlin, April 2009.

Developed in the 80’s the Target Controlled Infusion (TCI) theory was first commercially available in the 90’s associated to a unique molecule, the Diprivan. By combining a pre-filled syringe with an electronic tag, and a syringe pump integrating Diprifusor the technique was proposed to simplify IV anaesthesia and to provide a competitive and a clinical advantage to this molecule.

In 2003, Fresenius Kabi opened the TCI practice to the generic Propofol and to two opioids (Sufentanil and Remifentanil) with the launch of the Base Primea. Other companies then decided to propose their own so-called “open TCI” syringe pumps.

First driven and managed by a pharmaceutical company in collaboration with Infusion Pump companies the regulatory process was then in the hands of the Medical Devices companies to make the technique independent from a unique molecule and to allow its expansion.

Medical Devices companies are subject to the CE marking process and each company developed its own regulatory strategy mainly based on a review of the literature to select one (or more) pharmacokinetic model and based on the design of user interfaces that makes the use of the device safe by providing users with information they used to have with a standard administration mode, such as the flow rate profile associated to a change in the concentration target.

The main issue is associated with the choice of the pk/pd model for a specific IV drugs and to the corresponding patient population on which this model is validated. This has led to the availability of different pk/pd models for the same IV drugs depending on the syringe pump manufacturer, which is creating confusion for users who are not familiar with the TCI technique, and therefore limits the expansion of the technique despite its clinical benefits.

This could be overcome following 3 different strategies:

PK/PD models have to be integrated into the prescribing information provided by the pharmaceutical companies. In this case, these companies have to find an economical interest to justify the associated investment. This will reinforce the development of captive solutions and thus limits the expansion of the technique only to new IV drugs that are not yet in the public domain.

  • The different IV pumps companies agree on the pk/pd models they integrate in their devices based on a consensus that could be found between their respective clinical advisory boards. This has the advantage to simplify the process but it limits its transparency.
  • An independent clinical and scientific committee (TCI committee) under the umbrella of a scientific society such as the WorldSIVA defines the pk/pd models valid for a specific IV drugs and for a specified patient population. This committee could also review the dossier provided by a specific company and provide it with its recommendation that could be public.

The latter strategy is probably the more complex one to set up, but the most valuable on a long term basis. It will have the advantage to limit the number of pk/pd models available independently from the necessary competition between the device manufacturers. It will allow reinforcing teaching of the TCI techniques by providing the local scientific societies with clear guidelines.

But to really make the TCI technique a recognised and valuable administration technique it has to be expanded to IV drugs outside the single anaesthesia field and especially for IV drugs used in Intensive Care such as antibiotics for example. The clinical benefits have also to be more demonstrated and published to justify changes in the user’s habit.

Despite more than 25 years experience, the TCI technique is still in the development phase and both the scientific community and the medical device industry have to find a new way of collaboration to avoid seeing this technique remaining a technique for experts understood and supported only by a small group of scientists.

This collaboration could be based on:

  • funding an independent TCI committee by all major players which will gain the right to use the results of its work (such as the Bluetooth consortium).
  • having strong relationship between Medical Device industry official representative such as the Eucomed and the TCI committee to define short, mid and long term strategies.
  • developing educational program using the EuroSIVA and other local or regional societies expertise.
  • developing lobbying towards the pharmaceutical companies to integrate the development of pk/pd models when possible into the prescribing information.
  • developing a research program to continue to demonstrate the clinical benefits of the TCI technique.

The TCI technique needs a new dynamic, only a joined action by both the industry and the scientific community can create this dynamic.

Stephane Ruton
Fresenius Kabi
Strategic marketing director for Acute Care IV Delivery Systems

Filed Under: Fresenius Kabi, Industry

December 19, 2008 by admin

Two Important Aspects

Cardinal Health would like to highlight two important aspects for the benefit of a proper implementation of the models.

Firstly, products like the original model for prefilled Diprivan, or the one from other pump manufacturers or Alaris (R) PK from Cardinal Health are basically running a similar 3 compartments algorithm mathematical model that is also similar to those used by PC based software existing solutions. If the user interface vary from one device to the other, only due to difference of technology and mechanical interface, the same basic principle apply to every one. The fact is that delivery profile depends only on the selected Model (e.g. Marsh) with its set of parameters, applied to this 3 compartments algorithm. Therefore as manufacturer, Cardinal Health, with its mathematical calculation algorithm, does not need necessarily an open source code for improvement. However from a model implementation code point of view, this can contribute to reach a better consensus in models selection and application of better defined limitations in models parameters.

Secondly, from a regulatory standpoint, integration of Prescribing Information for TCI for a given drug, into the Medical Devices, is the natural way of implementing TCI technology but unfortunately it does not exist for all drugs or for all countries. The trick for medical device companies is to select and extend the offer to models not in drugs PI but those that have demonstrated their superiority based on the existing publications. In that case, the responsibility of the Anaesthesiologist for giving the right prescription by the selection of delivery profile (the drug/model selected/parameters) is paramount and company role here is to help reducing foreseeable misuse and use errors. Therefore, Cardinal Health Product, which already informs users on the display when a chosen profile is not mentioned in the drug prescribing information, believe that safety would benefit from an agreed definition of parameters limitations and a limitation consensus of the key models to be used.

The main contribution of companies providing TCI solutions was to integrate all in one Medical Device, compliant to regulations, and capable to deliver accurately the prescription by selection of the infusion profile based on models and parameter selection. This compliance is achieved by an extensive hardware and software validation required for such devices (including is operating system and its mathematical library). This is not reasonably possible to achieve this with Personal computers using Windows or Linux operating systems with serial connection to pumps.

Cardinal Health would then agree in supporting an open source PC software initiative in order to develop robust and flexible training and simulation tools, knowing that this code, if similar to those implemented in medical devices, can never match exactly the code required for Medical Device integration.

Stefano Zanetti, Marketing Director
Norbert Niedworok, Medical Director
Matt Richardson, R&D Director
Pierre Rebours, Regulatory Manager

Cardinal Health International
A-One Business Centre
CH-1180 Rolle
Switzerland

Filed Under: Cardinal Health, Industry

Search

Recent Posts

  • The Wrong Language
  • opentci.org finally back up!
  • Target-Controlled Infusions: Paths to Approval
  • Future TCI Issues and Industry
  • Two Important Aspects

Featured Posts

The Wrong Language

The following Clinical Perspective is contributed by Dr Tom Peck, Consultant Anaesthetist, Hampshire Hospitals NHS Foundation Trust The language of the TCI pump at induction is not the language of … [Read More...]

About Us

The Open TCI Initiative was developed initially by Dr Charles Minto (Sydney, Australia) & Professor Thomas Schnider (St Gallen, Switzerland) based on many discussions over the past years. This opentci.org website was born on 6 January 2008.

The three main goals of the Open TCI Initiative were further developed in discussion with our mentor, Professor Steven L. Shafer, on 17 January 2008 and others at the first meeting in Cape Town on 3 March 2008.

Learn more about us.

Recent Posts

  • The Wrong Language June 25, 2016
  • opentci.org finally back up! May 21, 2016
  • Target-Controlled Infusions: Paths to Approval May 21, 2016
  • Future TCI Issues and Industry June 17, 2009
  • Two Important Aspects December 19, 2008

Search

Copyright © 2025 · Executive Pro Theme on Genesis Framework · WordPress · Log in